Life Science Filter

Protecting Life with Biosecurity Filtration

Integrity Test Dolintestor FT 3.0

  • Dolintestor FT 3.0 Integrity Tester is a high-quality testing instrument independently developed by Feature-tec according to the current GAMP guidelines. It ensures accurate testing of filter integrity with short testing time and high accuracy, suitable for any cleanroom environment. 
    Dolintestor FT3.0 Integrity Tester provides testing functions including manual bubble point, basic bubble point, enhanced bubble point, diffusion flow, water intrusion, and pressure decay. It not only meets the integrity testing requirements of sterilizing filters but also meets the integrity testing requirements of ultrafiltration membrane cartridges and hollow fiber membranes. The testing scenarios can be both offline and online.

     

    Advanced Bio-Pharma Filtration Solutions

    Enhance yield and ensure compliance with Feature-Tec’s precision-engineered filtration technologies.

    • Targeted Applications: mAb Production, Vaccine Processing, ADC Manufacturing, & Fermentation.

    • Core Technologies: Depth Filtration, Bioburden Reduction, & Automatic Integrity Testing.

    • Expert Services: Full Process Validation & Technical Support.

    Global Compliance Guaranteed: Certified to GMP, USP, ICH, ISO 17025, EMA Annex 1, and PIC/S standards.

    Optimize your process today: marketing@feature-tec.com

     

    High performance

    • Excellent internal sealing performance to ensure the test data accuracy.
    • Optimized algorithm and automatic adjustment of intake air flow to shorten the test time.
    • Intelligent analysis capability by excluding human error in the test results, and fake cartridge test pass at extreme situation.

     

    Testing security

    • Ex "nA" explosion-proof design concept with whole machine, equipped with explosion-proof functionality, suitable for more demanding environments;
    • IP64 protection rating, reducing the risk of cross-contamination during transportation across clean areas;
    • Robust LINUX operating system significantly reduces the risk of virus infection after networking;
    • Username-password login with 4 levels of management permissions, meeting FDA 21 CFR PART 11 requirements;
    • Comprehensive audit tracking function, recording operation logs to meet data integrity requirements.

     

    Convenience

    • Easy to carry with 9.8kg machine weight
    • 12" HD HMI with ±88° viewing angle and 1024*768 resolution for easy operation and remote monitoring.
    • Simplified operation interface to reduce repetitive input.
    • Rich data interfaces: Ethernet port, RS232 serial interface, USB interface; capable of printing and exporting test results independently.

     

    Reliability

    • Adopt 1% of full-scale high-precision digital pressure sensor to ensure high accuracy and repeatability of the test results.
    • Run self-test before every function tests to avoid distortion of test data caused by human installation errors.
    • Each test point is accurately displayed to ensure the test curve accuracy.

     

    Dolintestor FT 3.0 Parameters

    Series: Dolintestor FT 3.0

    Dustproof Grade: IP54

     

    Computer

    • Power: AC100-240V, 50/60HZ, 110W
    • Operating System: LINUX
    • Display: Type: Color touchscreen; Size: 12 inches; Resolution: 1024*768
    • Serial port connection: Ethernet port; RS232; USB port; Wi-Fi; remote system updates and remote fault diagnosis

     

    Dimension/Weight

    • Dimension/mm: 346457308 (LWH)
    • Weight/kg: 9

     

    Testing Performance

    • Max. Operating Pressure: 10000mbar
    • Min. Inlet Pressure: 100mbar
    • Testing Function: manual bubble point test / basic bubble point test / enhanced bubble point test / diffusion flow test / water intrusion test / pressure decay
    • Testing Scope: Bubble Points 100-8000mbar; Diffusion Flow ≤0.01-4800mL/min; Water Intrusion ≤0.001-100mL/min
    • Testing Accuracy: Bubble Points: ±50 mbar; Enhanced bubble point: ±50mbar; Diffusion Flow: ±5% or 0.05 mL/min (whichever is greater); Water Intrusion: ±5% or 0.05 mL/min (whichever is greater)
    • Applicable Range: Symmetric and asymmetric membranes, needle filters, disc filters, capsule filters, flat filters, cartridge filters, ultrafiltration membrane cartridges, hollow, virus removal filter

     

    Data Management

    • Pre-storage program: max. 1000 pre-storage programs
    • Data storage: max. 50000 test results storage
    • Users: 1000 user accounts
    • Administrative privileges: Username-password login with 4 levels of administrative permissions, compliant with FDA 21 CFR Part 11 requirements
    • Audit trail: Multiple event logs, exportable in a non-modifiable format, meeting data integrity requirements
    • Data export: Individual export of PDF files or batch export of PDF files supported
    • Data backup: Supports export to USB drive

     

    Operating Conditions

    • Environmental requirements: Environmental temperature: +5℃ to +40℃; Relative humidity: 10% to 80%
    • Suitable Environment: Grade D or above

    Method: Online / Offline

    Language: Chinese / English / Russian / Japanese / Korean / Portuguese

    Print: Built-in micro printer, print test results and test curves

    E-Signature: Supports manual or electronic signatures

Integrity Test Dolintestor  FT 3.0
+
  • Integrity Test Dolintestor  FT 3.0

Product Parameters

  • 型号:Dolintestor l

    Overall dimension (LxWxH)mm

    346X457X308

    Weight kg

    ≈ 9.8

    Maximum power W

    110

    Display

    12"

    Explosion-proof design

    GB3836.142区;Ex II C "nA"

    Dustproof level

    IP64

    Intake pressure

    4000-8000mbar

     

    Test Method

    bubble point

    Enhanced bubble point

    water intrusion

    pressure decay

    diffusion flow

     

     

    Test accuracy

    Pressure measurement accuracy

    0.1% full scale

    bubble point

    ±50 person

    water intrusion

    <0.4 ml/min, ±0.02 ml/min.
    ≥0.4ml/min, ±5%

    pressure decay

    ±1mba

    diffusion flow

    <20ml, ±1ml/min
    ≥20ml, ±5�z

    volume determination

    ±4%

     

    Test Method

    bubble point

    50-6600mabr

    water intrusion

    0.005-6000ml/min

    pressure decay

    0.1-6600mba

    diffusion flow

    0.01-4800ml/min

    Communication Port

    Modbus TCP automation communication, wifi, RJ45 networking and data transmission, 3 USB software upgrades, barcode scanning.

    Printer

    heat sensitive

    Manage Permissions

    Multi-level management permissions

    Storage

    4G

    Operating System

    Linux

    Electronic signature

    Audit Trail

    Language selection

    Chinese/English

    document management system

Related components

Related Equipment

Message consultation


+86
  • +86 CN
Submit
%{tishi_zhanwei}%