Russia Centrifugal Filter Device Featain

Product Description

The Featain centrifugal filter device provide rapid ultrafiltration, making it easy to concentrated substances from diluted and complex sample. The ultrafiltration membranes enable rapid sample processing with high recovery, achieving concentration capabilities of up of tens times. It can reduce solute polarization and membrane contamination. Generally, the sample processing time is a few minutes or several tens of minutes, depending on the sample conditions (related to the molecular weight cutoff). The concentrate can be collected using a pipette, while the ultrafiltrates is collected in the provided centrifuge tubes.

 

Advanced Bio-Pharma Filtration Solutions

Enhance yield and ensure compliance with Feature-Tec’s precision-engineered filtration technologies.

  • Targeted Applications: mAb Production, Vaccine Processing, ADC Manufacturing, & Fermentation.

  • Core Technologies: Depth Filtration, Bioburden Reduction, & Automatic Integrity Testing.

  • Expert Services: Full Process Validation & Technical Support.

International Standards & Regulatory Compliance

Feature-Tec Sterilizing-Grade Filter Certifications & Compliance

1、Core Function & Definition (Sterilizing-Grade Identity)

Standard

Description

ASTM F838

Validated to the internationally recognized "gold standard" for bacterial retention in sterilizing-grade filters

PDA TR No. 26

Establishes scientific correlation between integrity testing and bacterial retention performance

21 CFR 211.65

Compliant with FDA requirements for material safety of pharmaceutical manufacturing equipment

 

2、Biosafety & Patient Safety

Standard

Description

USP <88> / ISO 10993

Validated for biocompatibility per USP Class VI and ISO 10993 requirements

USP <85> / EP 2.6.14

Complies with bacterial endotoxin limits to support injectable product safety

ICH Q3D / USP <232>

Complies with elemental impurity control requirements

USP <788>

Complies with sub-visible particulate matter requirements for injectable quality

BPOG Protocol (2014)

Characterized per BPOG extractables protocol to support chemical compatibility assessment

 

3、Manufacturing Process & Batch Consistency

Standard

Description

ISO 11137 (VDmax)

Validated for gamma irradiation sterilization, achieving SAL 10⁻⁶ sterility assurance level

ICH Q1A (R2), Q1E

Validated through accelerated and long-term stability studies to support claimed shelf life

ISO 9001 / 13485

Certified to quality management systems, ensuring consistent product quality and full traceability

 

4、Process Operations & Performance

Standard

Description

USP <643> / <645>

Post-flush residuals comply with USP Water for Injection (WFI) quality requirements

ISTA 2A / ASTM F2096

Validated for packaging integrity to maintain sterile barrier during transportation

 

5、Regulatory & Supply Chain Compliance Statements

Standard

Description

21 CFR 177-182

Materials comply with FDA requirements for indirect food-contact materials

GMO (EC) / BSE/TSE / BPA

Supporting declarations available: Non-GMO, BSE/TSE-Free, BPA-Free (where applicable)

 

Product Features
  • Lid, filter, and centrifuge tube assembly
  • PES ultrafiltration membrane
  • Ultra-fast rotation time
  • Translucent shell and volume scale for easy sample monitoring
  • Low protein adsorption

 

Typical Applications
  • Concentration and separation of biological samples such as antigens, antibodies, enzymes, nucleic acids, or microorganisms
  • Purification of macromolecular components in culture media extraction solutions and cell lysates
  • Diluted or pre-purified proteins in the elution buffer of concentration columns
  • Desalting, buffer exchange, and protein dialysis

 

Parameters 
Parameter Centrifugal Filter Device
Specification 15mL
MWCO 3kD, 10kD, 30kD, 50kD, 100kD
Construction Tubing Material: PPCap Material: PEMembrane: PES
Biosafety Components materials meet the criteria of the USP<88> Biological Reactivity for Class VI
Clealiness Comply with FDA 21 CFR 211.72 and 210.3(b)(5)(6) for no fiber release filters, and USP <788> for insoluble particulate levels in the flush water
Material Toxicity Component materials meet USP <88> Class VI plastics biological reactivity standards
Endotoxin <0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Manufacture Environment Manufactured in the 100,000 class clean room
pinterest-site-verification=3a23c4fadb8fb869f45e0b126990b7b1